Interventional Cardiology and Structural Heart Diseases

Home / Products and IT Solutions / Interventional Cardiology and Structural Heart Diseases
Artificial Intelligence Vascular Surgery Brain Surgery in Oncology Spinal Neurosurgery Radiology & Angiography Vascular Neurosurgery Interventional Oncoradiology Endoscopic Surgery Nuclear Medicine Interventional Cardiology

Acute Coronary Syndrome Treatment

Supraflex Cruz Coronary Stent System with Sirolimus Coating

The stent material is a cobalt-chromium alloy with cobalt content of at least 55%. Strut thickness is no more than 0.06 mm (60 micrometers). Drug coating – sirolimus. Diameter range: 2.0; 2.25; 2.5; 2.75; 3.0; 3.5; 4.0; 4.5 mm. Length range: 8, 12, 16, 20, 24, 28, 32, 36, 40, 44, 48 mm. Any listed diameter can be combined with any listed length.

Tetrilimus Coronary Stent System with Everolimus Coating

The stent material is a cobalt-chromium alloy with cobalt content of at least 55%. Strut thickness is no more than 0.06 mm (60 micrometers). Drug coating – everolimus. Diameter range: 2.0; 2.25; 2.5; 2.75; 3.0; 3.5; 4.0; 4.5 mm. Length range: 8, 12, 16, 20, 24, 28, 32, 36, 40, 44, 48 mm. Any listed diameter can be combined with any listed length.

Wilma SC Semi-Compliant Balloon Catheter for PTCA

Designed for percutaneous transluminal coronary angioplasty (PTCA). RX delivery system with a single lumen. Inflated balloon diameter: 2.00 mm; 2.25 mm; 2.50 mm; 2.75 mm; 3.00 mm; 3.50 mm; 4.00 mm; 4.50 mm. Effective balloon length: 9 mm; 13 mm; 15 mm; 17 mm; 20 mm; 25 mm; 29 mm; 33 mm; 37 mm; 41 mm. Rated burst pressure: 16 atm and 14 atm for sizes 4.50 mm and 5.00 mm. Max guidewire diameter: 0.36 mm (0.014”). Guide catheter ID ≥ 1.67 mm (5 F).

Wilma NC Non-Compliant Balloon Catheter for PTCA

Designed for percutaneous transluminal coronary angioplasty (PTCA). RX delivery system with a single lumen. Inflated balloon diameter: 2.00 mm; 2.25 mm; 2.50 mm; 2.75 mm; 3.00 mm; 3.50 mm; 4.00 mm; 4.50 mm. Effective balloon length: 6 mm; 8 mm; 10 mm; 12 mm; 15 mm; 20 mm; 25 mm; 29 mm. Nominal pressure: 12 atm. Rated burst pressure: 20 atm. Max guidewire diameter: 0.36 mm (0.014”). Guide catheter ID ≥ 1.67 mm (5 F).

Hydra™ TAVI

Hydra™ THV is a modern self-expanding transcatheter aortic valve for minimally invasive treatment of severe aortic stenosis. Its three-zone frame design combines low radial force in the outflow zone for aortic adaptation, high hoop strength in the middle section for valve roundness, and high radial force in the inflow zone for secure annular fixation.

COCOON Occluders

Occluder for minimally invasive percutaneous closure of ASD, VSD, PDA, and PFO. A safe device detachment system using a screw connection between the delivery cable and the occluder allows controlled release of the device and ensures the possibility of retrieval and removal of the occluder if necessary.

Connect us:
On any questions regarding complains about products quality, please contact our call center: + 7 (727) 339-05-32

© 2025 “Oliva” LLP. All right reserved.
About Education Events Clinical Studies Contact us Career